Marina Place Waterproofing and Structural Strengthening
LOCATION
STRUCTURE
- Mid-rise condominium
- Stucco over CMU exterior walls
PROBLEM
- Water intrusion
- Structural issues
SERVICES
- Investigation
- Repair design
- Construction observation
Condo Water Intrusion Investigation Reveals Structural Issues
Marina Place is a 7-level condominium building in Dunedin, Florida near the Gulf of Mexico. The building’s façade consists of a combination of direct-applied stucco over CMU exterior walls and lath-backed stucco over building paper and metal stud framing.
Residents of the building were experiencing significant water intrusion, including water dripping from the middle of ceilings and along the perimeter of the exterior wall at the floor. The stucco exhibited cracks, spalls, rust stains, and blisters of trapped water. There was also some concrete spalling on exterior walkways.
Walker Consultants performed a thorough investigation with a combination of visual observations, water testing, and invasive interior and exterior openings. The goal of the investigation was to understand the building’s construction, observe conditions of the existing materials, and better understand the water intrusion sources and potential remedies.
Matt Dougherty, PE
Principal, Director – Building Envelope, Forensics & RestorationWalker determined that the causes of the water intrusion were cracks in the stucco and exterior CMU wall, concrete spalls at windowsills, and poor sealant installation around windows. The water traveled through the cracks and spalls, down the hollow cells of the exterior wall CMU block, and under the unit flooring into the ceiling of the units below.
Walker designed the recommended repairs and prioritized them as three separate projects, providing the condo association with potential costs for each project. The repairs could be spread across multiple years, with the major leak repairs prioritized first.
As construction began, an additional issue was discovered. The exterior CMU block wall should normally have been reinforced with rebar to provide strength and resist wind loads, but no rebar was found. Walker recommended that this structural issue be addressed before the façade waterproofing work took place.
Marina Place now has a properly installed, warranted waterproofing system that will protect the strengthened concrete structure and protect the building and owners’ homes from water intrusion.
Related Projects
Bismarck, North Dakota
Bismarck Parkade Ramp Restoration
Restoration Consulting, Parking Structure Restoration
North Bethesda, Maryland
Structural Repairs for The Gables on Tuckerman
Structural Engineering, Restoration Consulting, Building Envelope for Existing Structures
Chicago. Illinois
Northwestern Memorial Hospital Arkes Pavilion Plaza
Restoration Consulting, Building Envelope for Existing Structures
Gainesville, Florida
University of Florida Asset Management Plan
Restoration Consulting, Parking Structure Restoration
Wilmette, Illinois
Mallinckrodt Plaza Waterproofing
Restoration Consulting, Parking Structure Restoration, Building Envelope for Existing Structures
Alexandria, Virginia
Parkfairfax Condominium Assessments and Repairs
Structural Engineering, Restoration Consulting, Building Envelope for Existing Structures
Peoria, Illinois
OSF HealthCare Structural Rehabilitation
Restoration Consulting, Parking Structure Restoration
Baltimore, Maryland
Bromo Seltzer Clock Tower Condition Assessment
Restoration Consulting, Building Envelope for Existing Structures
Houston, Texas
Keystone Lofts Structural Condition Assessment
Structural Engineering, Restoration Consulting
San Francisco, California
San Francisco Animal Care and Control Facility
Building Envelope for Existing Structures
Fernandina Beach, Florida
Peck Center Historic Preservation
Restoration Consulting, Building Envelope for Existing Structures
Washington, D.C.
Watergate South Concrete Balcony Repairs
Restoration Consulting, Building Envelope for Existing Structures
Commercial Office Building Roofing Design
Restoration Consulting, Building Envelope for Existing Structures
Eden Prairie, Minneapolis
Southwest Transit Bus Garage Air Conditioning Assessment
Structural Engineering, Building Envelope for Existing Structures
Jacksonville, Florida
Hodges Stadium Waterproofing
Restoration Consulting, Building Envelope for Existing Structures
Easton, Pennsylvania
Easton Hospital Building Envelope Asset Management Plan
Restoration Consulting, Building Envelope for Existing Structures
Greensboro, North Carolins
Piedmont Triad International Airport
Restoration Consulting, Operations & Technology
Columbus, Ohio
JPMorgan Chase Corporate Campuses Restoration
Restoration Consulting, Parking Structure Restoration
Columbus, Ohio
Easton Town Center Asset Management Plan
Restoration Consulting, Parking Structure Restoration, Building Envelope for Existing Structures
Bloomington, Minnesota
Appletree Square Condo Façade Restoration
Restoration Consulting, Building Envelope for Existing Structures
Detroit, Michigan
Book Tower Restoration
Restoration Consulting, Building Envelope for Existing Structures
Highlands Ranch, Colorado
Historic Windmill Restoration
Restoration Consulting, Building Envelope for Existing Structures
Omaha, Nebraska
Nebraska Medical Center Parking Structure Rehabilitation
Restoration Consulting, Parking Structure Restoration
Sioux Falls, South Dakota
Sioux Area Metro Transit Station Renovation
Restoration Consulting, Parking Structure Restoration, Building Envelope for Existing Structures
22 Cities in 17 States
Condition Assessment of Nationwide Parking Portfolio
Restoration Consulting, Parking Structure Restoration
Detroit, Michigan
David Stott Building Façade
Restoration Consulting, Building Envelope for Existing Structures
Houston, Texas
Lancaster Hotel Facade
Restoration Consulting, Building Envelope for Existing Structures
Ann Arbor, Michigan
Michigan Stadium Façade
Restoration Consulting, Building Envelope for Existing Structures
Galveston, Texas
Galveston Historic Facades Preservation
Structural Engineering, Restoration Consulting, Building Envelope for Existing Structures